Systems & equipment

Concrete Cooling Equipment Engineered as One Thermal System

Focusun coordinates flake ice production, storage, water chilling, dosing and controls around the batch plant and required concrete production profile.

System architecture

From Cold Production to Concrete Temperature Control

Each module is sized at the real duty point and integrated with material flow through the concrete batch plant.

01

Water Chilling

Low-temperature process water sized for base load and recovery.

02

Flake Ice

High cooling energy delivered directly into the mix water fraction.

03

Aggregate Cooling

Air or water-based cooling for the largest thermal mass in the mix.

04

Storage & Dosing

Buffers production peaks and meters cold energy into each batch.

05

Post-Cooling

Closed-loop circulation through embedded pipe networks.

System modules

Specified by Duty, Not Nominal Nameplate

Final selections depend on local climate, fluid temperatures, fouling allowance, utility quality and operating schedule.

CHW

Chilled-Water Plants

Air- or water-cooled packages, pumps, heat exchangers and insulated tanks configured for the required leaving-water temperature.

Base loadThermal storage
ICE

Flake Ice Systems

Focusun flake ice machines, refrigeration packages, ice silos, rake storage systems and weighing conveyors integrated with batch demand.

Peak loadAutomatic dosing
AGG

Aggregate Cooling

Cold-air or chilled-water methods selected for aggregate grading, moisture control, stockpile arrangement and cycle time.

High capacityMaterial handling
STR

Ice & Water Storage

Buffer capacity decouples refrigeration output from batch peaks and provides operating resilience during long pours.

Peak shavingRedundancy
CTL

Dosing & Controls

PLC sequences, temperature instruments, flow measurement and batch interfaces make cooling repeatable and traceable.

AutomationData logging
PCC

Post-Cooling Circuits

Pumps, manifolds, chillers and embedded piping control internal concrete temperature after placement.

Gradient controlClosed loop
Focusun industrial refrigeration and flake ice equipment fabrication

Industrialized delivery

Skid-Mounted Where Practical, Accessible, Maintainable and Ready for Site Integration

Scope boundaries

System Interfaces Are Part of the Engineering

A concrete cooling package fails at its interfaces long before it fails at its compressor.

Utilities

Connected electrical load, water quality, makeup, drainage and heat rejection.

Batch Plant

Weighing, sequencing, cycle time, control signals and operator interface.

Civil Works

Foundations, access, layout, pipe routes and maintenance clearances.

Operations

Start-up, standby, cleaning, spares, training and performance verification.